purplelasas.blogg.se

Ibm informix odbc 32 bit driver
Ibm informix odbc 32 bit driver







ibm informix odbc 32 bit driver
  1. #Ibm informix odbc 32 bit driver how to#
  2. #Ibm informix odbc 32 bit driver drivers#
  3. #Ibm informix odbc 32 bit driver driver#

Also, examine the General properties page. Open up your linked server's Security properties page and re-enter any connection password (even though asterisks - suggesting that the password is filled and correct - may appear in the corresponding entry).

ibm informix odbc 32 bit driver

PowerBuilder is a 32-bit application and requires 32-bit database software. Define the odbcini environment variable to point at your system wide i.

#Ibm informix odbc 32 bit driver driver#

In doing so, the existing linked server is dropped, and a new one is created. The setup routines for the IBM INFORMIX ODBC DRIVER could not be found. The ibm informix 32 bit odbc option will not be visible when using this utility. Press F5 to run the script and thereby apply your changes.

ibm informix odbc 32 bit driver

In the script text that appears, type replacement info for those settings that were grayed-out and uneditable.

#Ibm informix odbc 32 bit driver how to#

So, if your connection fails because you mistyped something, it is unclear how to fix it.īeneath "Test Connection," look for "Script Linked Server as."Ĭlick the latter, and, then, each of the following: "DROP And CREATE To" Once you create the linked server, if you go back into its General properties page, you will see that you cannot edit what you typed for Linked Server, Product Name (Why isn't this called "Provider Name," since Ifxoledbc is listed under Linked Servers/Providers in the Object Explorer tree?), Data Source, etc. The Data Source fill-in could be something as simple as rather than what I tried, namely, or (the latter specifies a port/service number). Progress DataDirects ODBC Driver for IBM Informix offers a high-performing, secure and reliable connectivity solution for ODBC applications to access IBM. If you used the automatic installation, and the ODBC driver is not recognized by Report Tool, uninstall any IBM informix driver that appear in Windows > Installed Programs.Reboot the PC and re-install the driver with the Unity Connection ODBC Setup Tool. If you use the version installed with CLI (version 2.8), it is recommended that you use version 2.5 of the. ODBC driver is not recognized by Report Tool. The more recent driver, the Intersolv Data Direct ODBC driver version 3.01, is a separate component in the list of options in the SDK install. Snapshots of the dialog boxes help immensely. The Informix ODBC driver, version 2.8, is automatically installed with Informix CLI version 2.8. The name of the ODBC driver depends on the version: IBM Informix ODBC Driver: For the Windows 32-bit driver, see Figure 3-1. It was hard for me to find such a clear, straightforward answer. To use Setnet32 on the Windows client, click on Start, Programs.

#Ibm informix odbc 32 bit driver drivers#

The answer of SGeis, above, is on the money. The Informix ODBC drivers are bundled in a suite of client connectivity products. Almost Done configuring your environment to connect to Informix. Give any data source name and fill appropriate connection details. I would have used the Comment feature, but I do not have enough "Reputation Points" to do so. Select IBM INFORMIX ODBC DRIVER and click finish.